A Quad Two-Way Optical Loss Test set (OLTS) that's perfect for medium to ultra high fiber count loss & length testing applications on both multimode fiber with a PC connector, and single mode fiber with an PC connector, at 850 / 1330nm & 1310/1550 nm. A pair of these compact SM & MM instruments set new standards of productivity, accuracy and ease of use. The 650 nm VFL VisiTester on both SM and MM ports mixes a VFL in with the test signal during Autotest. It operates as a stand-alone VFL, or gives positive visual identification of a fiber to be connected during loss testing.

Each fiber needs just one test hook-up and one key press for a complete bidirectional insertion loss and length test, and the same test method is used for both multimode and single mode fiber, eliminating administration, training and test errors. Testing is accurate and can take only 5 seconds, direct onto flexible standards-compliant Tier 1 certification reports.

A pair of instruments both display bi-directional loss and length, in real time, with no need to specify master/slave instruments. A single instrument can also be used as a stand-alone light source & power meter, VFL or tone generator / detector.

  • 25% of the size / weight, 7x the battery life of competitors
  • Bidirectional Autotest loss & length testing on one fiber
  • Real time Pass / Fail display
  • 8,000 fiber memory and USB Flash Drive file dump
  • KITS™ reporting software
  • Autotest optical power meter, >25 λ, 1 % accuracy
  • Traceable calibration reports: power meter & linearity, source λ & stability
  • 80 hr alkaline battery life
  • 3 Year warranty and calibration cycle
  • EF compliant multimode sources

Key Features

Specifications

KI27424LV-INGAAS specifications
Modulated output (source) 270 Hz, 1 kHz, 2 kHz ± 2 %, 12 Multi-Fiber ID tones
 
Output wavelength (source) Port 1: 1310, 1550 nm Laser / Port 3: 850, 1300 nm LED
 
Output power (source) -7 dBm ±1 dB (@ 9/125 µm for 1310, 1550 m) / -27 dBm ±1 dB (@ 62.5/125 µm for 850, 1300 nm)
 
Adjust output power (source) Adjustable over 7 dB in 0.01 dB steps (for 1310, 1550 nm) / Fixed (for 850, 1300 nm)
 
Wavelength initial tolerance @ 25 °C (source) 20 nm (for 1310, 1550 nm)
 
Short term stability for 15 min, typical ±2 °C, after warm up, ORL < -25 dB (source) 0.04 dB (for 1310, 1550 nm) / 0.01 dB (for 850, 1300 nm)
 
Stability over temperature (source) 0.6 dB (max for 1310, 1550 nm) / 0.35 dB (max for 850, 1300 nm)
 
Spectrum width @ FWHM (source) 3 nm (typical for 1310, 1550 nm)
 
Wavelength drift (source) 0.4 nm per °C (typical for 1310, 1550 nm) / 0.4 nm per °C (typical for 850, 1300 nm)
 
Mode controlled (source) 850, 1300 nm (50/125µm compliant: IEC 61280-4-1 {Ed.1.0}, TIA 526-14A & TIA TSB-178)
 
Reconnection repeatability @ 95% confidence (source) 0.1 dB (for 1310, 1550 nm Laser) / 0.05 dB (for 850, 1300 nm LED)
 
Length range (2-way Autotest only) 27 dB (for 1310, 1550 nm) / 4.5 dB @ 62.5um (for 850, 1300 nm)
 
Length accuracy (2-way Autotest only) 0.01% ± 4 meters
 
Length resolutions 1 meter (0.000~9.999 Km), 10 meters (10.00~99.99 Km), 100 meters (100.0~127.9 Km)
 
Loss range (2-way Autotest) 44 dB (for 1310, 1550 nm) / 24 dB @ 62.5 µm; 24.5 dB @ 50 µm (for 850, 1300 nm)
 
Loss repeatability & loss linearity (2-way Autotest) 0.04 dB (for 1310, 1550 nm) / 0.06 dB (for 850, 1300 nm)
 
Loss range (1-way Autotest) 44 dB (for 1310, 1550 nm) / 24 dB @ 62.5 µm (for 850, 1300 nm)
 
Loss repeatability & loss linearity (1-way Autotest) 0.04 dB (for 1310, 1550 nm) / 0.06 dB (for 850, 1300 nm)
 
VisiTester wavelength 650 ± 5 nm
 
VisiTester power 0 dBm ± 1 dB @ SMF
 
VisiTester laser safety Class 1, IEC60825-2
 
VisiTester blink rate (manual) CW or 2 Hz
 
Country of Origin Australia
 
Shipping Weight 1500 g
 
General Two-Way Loss / Length Test Set KI 27400 Series specifications
Detector type (meter) InGaAs
 
Response wavelength (meter) 600 ~ 1700 nm
 
Calibration wavelengths (meter) 780, 820, 850, 980, 1270, 1290, 1300, 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450, 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610, 1625, 1650 nm
 
Power range (meter) +10 ~ -60 dBm (780 ~ 980, 1590 ~ 1650 nm) / +10 ~ -70 dBm (1270 ~ 1650 nm)
 
Calibration accuracy (meter) 1 % (0.06 dB)
 
Mid-range linearity (meter) 0.04 dB (typical)
 
ID tone detection & Autotest sensitivity (meter) Up to -50 dBm
 
Resolution (meter) 0.01 dB
 
Polarization sensitivity (meter) < 0.05 dB (typical)
 
λ sensitivity, ± 30 nm. Selected λ 0.2 dB (typical)
 
Tone detection (meter) 150 ~ 9999 Hz ± 1 %
 
Autotest 1-way: compatible with other KI23400 & KI27400 models / 2-way: compatible with identical model only
 
USB interfaces Micro-USB or USB-C for power & software / USB-A Flash Drive
 
Software KITS (free download)
 
Power Battery / External power via micro-USB or USB-C. Charging is jumper selectable
 
Battery life Laser/LED source: 80 hours (typical) in Autotest, Power Meter: 1000 hours (typical)
 
Battery type 2x AA (LR6) Alkaline / 2x AA NiMH AA (rechargeable via USB-micro or USB-C)
 
Auto off Selectable
 
Display 74 mm x 55 mm high contrast LCD
 
Case Polycarbonate (body) / rubber (edges & corners), moisture resistance, 1-meter drop tested
 
Memory For 8,000 fibers / Unlimited on USB Flash Drive
 
Size 190 mm x 105 mm x 35 mm
 
Unit weight 0.42 kg
 
Shipping weight 1.5 Kg
 
Operating / storage temperature -15 to 55 °C / -25 to 70 °C
 
Relative humidity 0 ~ 95 %
 
Warranty 3 years
 
Calibration validity (ISO/IEC 17025) 3 years
 
IP Rating IP52
 

Documentation & Support

Sales literature

Related application notes

More application notes...

Manuals & software

Applications

In the box

Mandrel Wrap Filters, 50 & 62.5 um OPT701

22 mm mandrel for 3 mm patch lead, 50 u core. 17 mm mandrel for 3 mm patch lead, x 62.5 u core. FOTP-50 Method A

ST Hybrid Connector Adapter OPT040

ST-SC. Tough metal body, precision ceramic sleeve

SC/SC Through Connector OPT046

SC-SC, Tough metal body, precision ceramic sleeve

LC Hybrid Connector Adapter OPT076

LC-SC Simplex. Tough metal body, precision ceramic sleeve

Padded Canvas Carry Pouch OPT149

Soft pouch for two KI2000 series instruments. With carry straps and compartments for accessories storage.

Wrist Strap / Lanyard

Handy lanyard & matching instrument attachment point

Software (KITS)

Downloadable from Kingfisher's website for free.

USB Cable (Micro or C)

2 meter USB cable, A-to-Micro or A-to-C

Instrument User Manual

Comprehensive user manual, in well written English

Quick Reference Guide QRG

Handy quick reference guide, some in multiple languages

Traceable Calibration Certificate ILAC/NATA Compliant

IEC/ISO 17025 compliant calibration certificate

Optional accessories

OPT051

FC Hybrid Connector Adapter OPT051

FC-SC. OPT081 adaptor is preferred for power meters, since FC ceramic sleeves can break easily. Tough metal body, precision ceramic sleeve

OPT081

2.5 mm Universal Hybrid Connector Adapter OPT081

Universal 2.5 mm-SC, also compatible with duplex SC. Tough metal body, precision ceramic sleeve. Please observe application advice.

OPT085

1.25 mm Universal Hybrid Connector Adapter OPT085

Universal 1.25 mm-SC. Also fits: Duplex LC, Senko CS, SN duplex, and USconec MDC duplex connectors. Tough metal body, precision ceramic sleeve. Please observe application advice.

OPT080
OPT072

LC / F3000 Hybrid Connector Adapter OPT072

For F3000-SC PC Simplex. This is an LC-PC adapter that also fits F3000. For LC-PC only use, ceramic sleeve. OPT076 is better value and more robust.

OPT060

E2000 Hybrid Connector Adapter OPT060

E2000-SC, ceramic sleeve

OPT060G

E2000 Hybrid Connector Adapter Green OPT060G

E2000-SC, green, ceramic sleeve

OPT071

LSA-DIN47256 AVIM Hybrid Connector Adapter OPT071

AVIM / LSA / DIN47256 - SC. Ceramic sleeve

OPT154B

Semi-Rigid Carry Case for Test Kits OPT154B

Semi-rigid canvas test kit case for two KI2000 series instruments, three KI900 series instruments, optical microscope & VFL pen. With cleaning materials, carry straps and compartments for accessories storage. Moulded interior provides a perfect combination of durability, protection, and comfortable use.

OPT153-CASE

Semi-Rigid Carry Case for Test Kits OPT153-CASE

Semi-rigid canvas test kit case for two KI2000 or KI7000 series instruments, and three KI9000 series instruments. With carry straps and compartments for accessories storage. Moulded interior provides a perfect combination of durability, protection, and comfortable use.

TOOL CLEAN-09A

Fiber Connector Cleaner Cartridge TOOL CLEAN-09A

To clean a connector end face / tip, prior to connector insertion into a mating adaptor.

TOOL CLEAN-03

Stick-Type Cleaner 2.5 mm TOOL CLEAN-03

To clean the end face and mating sleeve of a fiber optic connector with 2.5 mm diameter ferrule. SC, FC, ST etc.

TOOL CLEAN-04

Stick-type Cleaner 1.25 mm TOOL CLEAN-04

To clean the end face and mating sleeve of a fiber optic connector with 1.25 mm diameter ferrule, LC, SN etc

© Kingfisher International, Australia, ABN 51 007 250 213